No |
380V Motor power |
Model |
Rated current of magnetic protection |
Remarks |
|
|
high speed |
low speed |
||||
|
1 |
5kw-75kw |
WDCPSD-16/M16/MX/06M |
16A |
X |
Fire fighting products
06M followed by F is 06MF,
X is the setting current value for low speed operation,
Selected by the designer
|
|
2 |
7.5kw-11kw |
WCDPSD-32/M25/MX/06M |
25A |
X |
|
|
3 |
11kw-15kw |
WDCPSD-32/M32/MX/06M |
32A |
X |
|
|
4 |
15kw-18.5kw |
WDCPSD-45/M40/MX/06M |
40A |
X |
|
|
5 |
18.5Kw-22kw |
WDCPSD-45/M45/MX/06M |
45A |
X |
|
|
6 |
22kw-30kw |
WDCPSD-63/63AM63/MX/06M |
63A |
X |
|
|
7 |
30kw-37kw |
WDCPSD-100/80AM80/MX/06M |
80A |
X |
|
|
8 |
37kw-45kw |
WDCPSD-100/100AM100/MX/06M |
100A |
X |
|
|
9 |
45kw-55kw |
WDCPSD-125/125AM125/MX/06M |
125A |
X |
|
Selection and design of VDCPSJ for star delta decompression startup
|
No |
380V Motor power |
Model |
Remarks |
|
1 |
11kw-15kw |
WDCPSJ-32/M32/06M |
For fire protection products, the added F after 06M is 6MF
|
|
2 |
15kw-18.5kW |
WDCPSJ-45/M40/06M |
|
|
3 |
18.5kw-22kw |
WDCPSJ-45/M45/06M |
|
|
4 |
22kw-30kw |
WDCPSJ-63/M63/06M |
|
|
5 |
30kw-37kw |
WDCPSJ-100/M80/06M |
|
|
6 |
37kw-45kw |
WDCPSJ-100/M100/06M |
|
|
7 |
45kw-55kw |
WDCPSJ2-100/M80/06M |
|
|
8 |
55kw-75kw |
WDCPSJ2-125/M100/06M |
|
|
9 |
75kw-90kw |
WDCPSJ2-125/M125/06M |
WDCPS model selection design
|
No |
380V Motor power |
Model |
Remarks |
|
1 |
0.08kw-0.1kw |
WDCPS-12/M0.25/08M |
For fire protection products, the added F after 06M is 06MF
For isolated products, add G after 06M to 06MG
Fire isolation type 06M with FG added after is 06MFG
|
|
2 |
0.1kw-0.2kw |
WDCPS-12/M0.4/06M |
|
|
3 |
0.2kw-0.27kw |
WDCPS-12/M0.63/06M |
|
|
4 |
0.3kw-0.45kw |
WDCPS -12/M1/06M |
|
|
5 |
0.5kw-0.7kw |
WDCPS-12/M1.6/06M |
|
|
6 |
0.6kw-0.8kw |
WDCPS -12/M2/06M |
|
|
7 |
0.8kw-1.1kw |
WDCPS-12/M2.5/06M |
|
|
8 |
1kw-1.3kw |
WDCPS -12/M3/06M |
|
|
9 |
1.2kw-1.8kw |
WDCPS -12/M4/06M |
|
|
10 |
1.9kw-2.6kw |
WDCPS -12/M6/06M |
|
|
11 |
2kw-2.75kw |
WDCPS-12/M6.3/06M |
|
|
12 |
3kw-3.5kw |
WDCPS-12/M8/06M |
|
|
13 |
3.5kw-4.5kw |
WDCPS -12/M10/06M |
|
|
14 |
4kw-5kw |
WDCPS-12/M12/06M |
|
|
15 |
5kw-7kw |
WDCPS -16/M16/06M |
|
|
16 |
7kw-9kw |
WDCPS-12/M20/06M |
|
|
17 |
9kw-11kw |
WDCPS -25/M25/06M |
|
|
18 |
11kw-15kw |
WDCPS-32/M32/06M |
|
|
19 |
12.5kw-18kw |
WDCPS -45/M40/06M |
|
|
20 |
14.5kw-20kw |
WDCPS-45/M45/06M |
|
|
21 |
16kw-22kw |
WDCPS -45/M50/06M |
|
|
22 |
20kw-26kw |
WDCPS-63/M63/06M |
|
|
23 |
28kw35kw |
WDCPS-100/M80/06M |
|
|
24 |
35kw-45kw |
WDCPS-100/M100/06M |
|
|
25 |
40kw-55kw |
WDCPS-125/M125/06M |
Summary
|
Operation sequence |
Show contents |
Code definition |
Set range |
Factory settings |
|
The first time Press the setting key |
] 16 |
Rated current |
Set within the protection value specification range |
Ordering requirements |
|
The second time Press the setting key |
H03 |
start delay |
0-99s |
3s |
|
The third time Press the setting key |
Fl |
Serial number of overcurrent inverse time protection action |
Within the range corresponding to No. 1-4 |
2 |
|
The fourth time Press the setting key |
P60 |
Percentage value of three-phase current unbalance |
About 20% - 75% difference between current and |
60% |
|
The Fifth time Press the setting key |
⊔ |
Overvoltage value |
0-999 |
120% |
|
The sixth time Press the setting key |
⊓ |
Undervoltage value |
0-999 |
75% |
|
The Seventh time Press the setting key |
﹂ |
Leakage current value code |
In the range corresponding to No. 1-8 |
6(Ordering requirements) |
|
The Eighth time Press the setting key |
▭ |
Undercurrent value |
0-999、Action time≤30s |
0.00le(Off by default) |
|
The ninth time-The Thirteenth time Press the setting key |
Ellipsis |
|||
After setting, press reset to exit the setting state and save the setting value.
Some functions need to be customized (specifically selected according to user needs).
Basic Electrical Control Diagram
|
Secondary power supply |
Power protection |
Power signal |
Local manual control |
Auxiliary signal |
Alarm signal |
||
|
Function |
Stop it |
Short circuit |
Fault |
||||
|
Secondary power supply |
Power protection |
Power signal |
Local manual control |
Auxiliary signal |
Alarm signal |
||||
|
Start |
Stop |
Self-locking |
Start |
Stop |
Short circuit |
Fault |
|||
Overall installation dimension